ANAESTH-ASSIST-3-GAS-MODEL

Standard Specification:

• Non Metallic water resistant and fire retardant moulded
body made from engineering grade polymer. 

• Back-lit illuminated 3-gas, cascaded 5-tube Rotameter.
• Selectatech bar for two temperature and pressure
compensated agent specific vaporiser.

• Diameter coded self sealing type inlet for piped gas (1 each
O2 , N2O and AIR) with non return. 

• Master switch for system ON/OFF for gases and power
supply.
• Common gas outlet. 

• Open/close circuit switch for easy change over from open to
close circuit.

• Integrated Power backup and extra electrical extension
outlets for running other devices.
• Integrated microprocessor based pneumatically driven ventilator.

• Interactive test for confirming proper device operation during start-up.

• Circle absorber system with integrated ventilator bellow, bag ventilator selector switch with active changeover.

• Pin indexed type yoke for bottled oxygen and Nitrous Oxide(1 each).

• Anaesthetic gas scavenging system port in Circle Absorber.

• Resistant to external Electro Magnetic Interference (Both Ambient and Conductive).

 

Note: Vaporisers Oponal ** Images shown here are for illustrave purpose only**
Venlator :

• Ventilation Mode : VCV, PCV, SIMV and Manual (Bag).
• Digital and compensated tidal Volume control in ventilator.

• Tidal Volume adjustment: 100 ~ 1500ml. I:E ratio: 4:1 to 1:4. Frequency Adjustment range: 1 ~ 60 (1 ~ 40 in SIMV mode).

• Monitoring: VTi, VTe, MV, BPM, FIO2 , PEEP, RR, I:E Ratio, Ppeak, Cdyn and CMV time.

• On the go changing of VT, BPM, I:E Ratio, PEEP, Itrig and Rising Rate.

• 7” Full Colour Touch Screen Display.
• Inbuilt FiO2 monitor with adjustable high and low alarm with FiO2 sensor calibration feature. 

• Flow sensor calibration data input feature.

• Waveform: Flow vs Time and Pressure vs Time (also available during Manual Bag Ventilation).

• Ventilatory loops: Volume vs Pressure and Flow vs Volume.

• Alarm for High and Low AWP, MV, FiO2 , Low oxygen pressure  and critical battery status.

• Electronic PEEP control from 0 ~ 20cm of water column.
• Pressure Trigger: -3~+19cm of water column (SIMV Mode).
• Pressure Limit: Patient airway 5~65 cm of water column.

• Airway pressure monitoring range: -3~100 cm of water.
• Accurate display of Inspiratory and expiratory volume using proximal flow sensor.
• Fresh gas flow compensation in all mode of ventilation.

• Animated inspiratory and expiratory phase during CMV.
• Audible alarm volume control.
• Reminder of audio alarm mute at every 120 seconds during alarm condition.

• Reminder of device running on battery backup after every 33 seconds.
• Ventilator set parameter data automatically saved and stored by the ventilator.

Paent Safety :

• Gear linked mechanical Hypoxic control device.

• Fresh gas compensation during inspiratory saving from Volutrauma.

• Nitrous oxide interlocking.

• Emergency Oxygen flush.

• FiO2 display (while using close circuit). 

• Breathing system pressure relief valve set at 1200mm of water column.

• Audio visual oxygen pressure alarm and critical battery alarm.

• Low and high airway pressure alarm.

• Low and high minute volume alarm.

• Low and high FiO2 alarm. 

• Waveform monitor during manual bag ventilation.

• Interactive test for confirming proper device operation during start-up.

• Circle absorber system with integrated ventilator bellow, bag ventilator selector switch with active changeover.

• Pin indexed type yoke for bottled oxygen and Nitrous Oxide(1 each).

• Anaesthetic gas scavenging system port in Circle Absorber.

• Resistant to external Electro Magnetic Interference (Both Ambient and Conductive).

• Interactive test for confirming proper device operation during start-up.

• Circle absorber system with integrated ventilator bellow, bag ventilator selector switch with active changeover.

• Pin indexed type yoke for bottled oxygen and Nitrous Oxide(1 each).

• Anaesthetic gas scavenging system port in Circle Absorber.

• Resistant to external Electro Magnetic Interference (Both Ambient and Conductive).