ANAESTH-ASSIST-2-GAS-MODEL
Standard Specification:
• Non Metallic water resistant and fire retardant moulded body made from engineering grade polymer.
• Back-lit illuminated 2-gas, cascaded 4-tube Rotameter.
• Selecta tech bar for one temperature and pressure compensated agent specific vaporiser.
• Diameter coded self sealing type inlet for piped gas (1 each) with non return.
• Master switch for system ON/OFF for gases and power supply.
• Common gas outlet.
• Open/Close circuit switch for easy change over from open to close circuit.
• Integrated Power backup and extra electrical extension outlets for running other devices.
• Integrated microprocessor based pneumatically driven ventilator.
• Interactive test for confirming proper device operation during start-up.
• Circle absorber system with integrated ventilator bellow, bag ventilator selector switch with active changeover.
• Pin indexed type yoke for bottled oxygen and Nitrous Oxide(1 each).
• Anaesthetic gas scavenging system port in Circle Absorber.
• Resistant to external Electro Magnetic Interference (Both Ambient and Conductive).
Venlator :
• Ventilation Mode : VCV, PCV, SIMV and Manual (Bag).
• Digital and compensated dal Volume control in ventilator.
• Tidal Volume adjustment: 100 ~ 1500ml.
• I:E ratio: 4:1 to 1:4.
• Frequency Adjustment range: 1 ~ 60 (1 ~ 40 in SIMV mode).
• Monitoring: VTi, VTe, MV, BPM, FIO2 , PEEP, RR, I:E Ratio, Ppeak, Cdyn and CMV time.
• On the go changing of VT, BPM, I:E Rao, PEEP, Itrig and Rising Rate.
• 7” Full Colour Touch Screen Display.
• Inbuilt FiO2 monitor with adjustable high and low alarm with FiO2 sensor calibration feature.
• Flow sensor calibration data input feature.
• Waveform: Flow vs Time and Pressure vs Time (also available during Manual Bag Ventilation).
• Ventilatory loops: Volume vs Pressure and Flow vs Volume.
• Alarm for High and Low AWP, MV, FiO2 , Low oxygen pressure and critical battery status.
• Electronic PEEP control from 0 ~ 20cm of water column.
• Pressure Trigger: -3~+19cm of water column(SIMV Mode).
• Pressure Limit: Patient airway 5~65 cm of water column.
• Airway pressure monitoring range: -3~100 cm of water.
• Accurate display of Inspiratory and expiratory volume using proximal flow sensor.
• Fresh gas flow compensation in all mode of ventilation.
• Animated inspiratory and expiratory phase during CMV.
• Audible alarm volume control.
• Reminder of audio alarm mute at every 120 seconds during alarm condition.
• Reminder of device running on battery backup after every 33 seconds.
• Ventilator set parameter data automatically saved and stored by the ventilator.
Paent Safety :
• Gear linked mechanical Hypoxic control device.
• Fresh gas compensation during inspiratory saving from Volutrauma.
• Nitrous oxide interlocking.
• Emergency Oxygen flush.
• FiO2 display (while using close circuit).
• Breathing system pressure relief valve set at 1200mm of water column.
• Audio visual oxygen pressure alarm and critical battery alarm.
• Low and high airway pressure alarm.
• Low and high minute volume alarm.
• Low and high FiO2 alarm.
• Waveform monitor during manual bag ventilation.